The 1342 can be regulated without a frequency counter, if you aren't rich (the devices cost a fortune), are careful, have the correct driver to adjust the trim capacitor so you don't break it, and move the capacitor adjustment in VERY small increments. A proper cleaning is recommended first, as this is a very old movement. However, if you can't do that, at least clean the surface of the electronic board with 100% solvent (I used either pure ethanol or heptane). I have found that the trim capacitor doesn't work properly if the board isn't cleaned, so a wipedown with solvent is a minimal step). Set the watch against an official time reference such as time.gov, and make each correction after say 24hrs. The trim capacitor adjustments appear to be the reverse of most quartz movements, here clockwise slows, counterclockwise speeds. Doing this I have regulated 1342 movement to better than 10sec/month, i.e. less than 1 sec/day.
The movement perhaps has 40-50 year old lubricants, so a cleaning and overhaul is certainly a good idea. Moebius quartz oil seems to be adequate, but the cannon pinion can be problematic, and a proper grease is needed for it or the date won't advance at midnight. Unfortunately, the recommended greases cost a fortune. Finally, the keyless works is tricky, and if you don't have it set correctly you won't get the stem and crown to set. That may cause you to fume, and have to disassemble the movement... The correct Renata 329 battery can be purchased on line.